Shenzhen Link-Card Tech Co., LTDMenu

Infrared Thermal Imaging Handheld Solution: Low Power Compact Design for Portable Observation

Infrared Thermal Imaging Handheld Solution: Low Power Compact Design for Portable Observation

    T1N Infrared Thermal Imaging Handheld Observation Product

    1. Overview

    The T1N series handheld thermal observation products are built around the Link-Card Tech LC221 infrared camera module, targeting outdoor search and observation, night-time inspection and security surveillance applications. The products use an uncooled vanadium oxide (VOx) microbolometer detector operating in the 8-14μm long-wave infrared (LWIR) atmospheric window, delivering all-weather passive thermal imaging without any cooling requirement. The system core consists of the infrared detector, an ARM+DSP signal processing platform, a 0.39-inch OLED microdisplay and a Wi-Fi image transmission module; total system power consumption is held to 1.2W-1.5W, powered from a 1S lithium battery.

    The 640×512 resolution is the mainstream recommended configuration for the T1N, offering superior thermal sensitivity (NETD≤35mK) and longer recognition range, and is suitable for the vast majority of observation applications. The 384×288 configuration is available as a standard economy option for entry-level applications with tighter budgets. Both configurations share the same detector pixel pitch (12μm), spectral response range and optical interface (M25×0.5). A future upgrade to a 1280×1024 high-definition detector will further improve image resolution and fine-detail discrimination.

    2. Technical Specifications

    The table below lists the complete technical specifications for both T1N resolution configurations, with 640×512 as the mainstream recommendation. NETD (noise equivalent temperature difference) is the key metric for thermal sensitivity: ≤35mK for the 640×512 configuration and ≤40mK for the 384×288 configuration, the 640×512 version achieving higher thermal sensitivity through an improved readout circuit design. The 1280×1024 high-definition configuration, offered as a future upgrade option, will provide four times the pixel count of 640×512 and suits professional applications demanding the finest detail discrimination.

    Parameter 384×288 Configuration 640×512 Configuration
    Detector Type Uncooled Vanadium Oxide Same as left
    Resolution 384×288 640×512
    Pixel Pitch 12μm 12μm
    Spectral Response 8-14μm 8-14μm
    Frame Rate 25/30/50Hz 25/30Hz
    NETD ≤40mK@25℃,F#1.0 ≤35mK@25℃,F#1.0
    Display 0.39" OLED 1024×768@50Hz Same as left
    Wi-Fi Transmission Supported (2.4GHz) Supported (2.4GHz)
    Lens Mount M25×0.5 M25×0.5
    Battery 1S Lithium Battery 1S Lithium Battery
    Storage Capacity 32GB 32GB
    Charging Interface USB Type-C USB Type-C
    Dimensions (excl. module) 41.15×35.9×32mm 39.85×35.9×32mm
    Weight (excl. module) 52g 55g
    Power Consumption 1.2W 1.5W
    Operating Temperature -20℃~60℃ -20℃~60℃

    3. System Architecture

    The T1N system architecture is organised into four layers: the optical layer, the detector layer, the signal processing layer and the display output layer.

    Optical layer: the infrared lens uses an M25×0.5 threaded mount with germanium glass elements, transmittance ≥90%@8-14μm. Lens F# options are F1.0/F1.1/F1.2 — a smaller F# means a larger clear aperture and better NETD. The lens focuses target infrared radiation onto the detector focal plane.

    Detector layer: after absorbing infrared radiation, the uncooled vanadium oxide microbolometer rises in temperature, changing the pixel resistance. The readout integrated circuit (ROIC) converts this resistance change into an electrical signal, which is quantised by a 14bit ADC and output as raw digital image data. The detector requires no cooler and is operational immediately at power-on; response time is governed by the thermal time constant (typically 10-14ms).

    Signal processing layer: an ARM+DSP dual-core processor handles the image processing workload. The processing pipeline includes non-uniformity correction (NUC) to eliminate pixel response variation; automatic gain control (AGC) to compress the 14bit dynamic range down to 8bit for display; pseudo-colour mapping to convert the greyscale image into a thermal palette; digital detail enhancement (DDE) to sharpen edges and texture; and 2D/3D noise reduction to suppress spatial and temporal noise. A shutter correction mechanism periodically closes the shutter to capture a reference frame, compensating for detector thermal drift.

    Display output layer: the 0.39-inch OLED microdisplay provides 1024×768@50Hz resolution, contrast ratio >10000:1 and response time <10μs, suiting high-speed scenarios. The display driver circuit converts the processed image data into OLED drive signals while overlaying HUD information such as the reticle, electronic compass bearing and battery level. The Wi-Fi module streams video to a mobile application over a 2.4GHz wireless link.

    4. Interface Definition

    Interface Type Specification Function
    USB Type-C 5V DC charging Power input / data transfer
    Wi-Fi 2.4GHz Image transmission / remote control
    OLED Display 0.39" 1024×768@50Hz Real-time image display
    Memory Card 32GB TF card Video / photo storage

    Imaging modes: four standard palette modes are supported. White-Hot renders hot targets as bright white against a black background for the highest contrast, suiting general observation. Black-Hot is the inverse of White-Hot, rendering targets in black and suiting scenarios where low-temperature detail must stand out. Red-Hot displays high-temperature regions in a red gradient for rapid hot-spot localisation. Pseudo-Colour applies a multi-spectrum mapping for professional analysis requiring fine temperature discrimination.

    5. Application Scenarios

    Outdoor search and observation: thermal imaging detects targets from the temperature difference against the background and does not depend on ambient illumination. In complete darkness, the human body (skin temperature approximately 33℃) presents a 10-18K temperature difference relative to the ground background (night-time temperature approximately 15-25℃); detection range depends on lens focal length and detector resolution. With an F1.0 lens, the 384×288 configuration achieves a human detection range of roughly 300-400m, while the 640×512 configuration reaches 500-600m under the same conditions. Detection, recognition and identification ranges decrease in an approximate 4:2:1 ratio according to the Johnson criteria.

    Environmental penetration: the 8-14μm band sits within an atmospheric window with high atmospheric transmittance. This band penetrates fog, smoke, dust and other aerosols relatively well — thermal signal attenuation is dominated by Mie scattering, so in light fog the effective working range is reduced by only 20-30%, whereas visible-light equipment may fail entirely under the same conditions. Rain and snow do attenuate thermal imaging to some degree (raindrops absorb and scatter at 8-14μm), but overall performance still exceeds that of low-light night vision.

    Night-time inspection and security surveillance support: for fixed-route inspection of power facilities, oil pipelines, border lines and similar assets, the T1N can be used as a handheld or portable thermal imager. Wi-Fi transmission pushes the live image to a smartphone or tablet so that remote personnel can view the thermal scene simultaneously and support decision-making.

    Field reconnaissance: the temperature difference between animal body heat and the environment makes thermal imaging highly effective for wildlife observation and search and rescue. Human subjects concealed by vegetation can still be detected by their thermal radiation, an ability to see through thin brush that visible-light equipment cannot match.

    6. Mechanical Dimensions

    The T1N unit (excluding the camera module) has a compact form factor compatible with mainstream rail mounting. The 384×288 configuration measures 41.15×35.9×32mm and weighs 52g; the 640×512 configuration measures 39.85×35.9×32mm and weighs 55g. The housing is aluminium alloy, balancing heat dissipation with light weight. The lens attaches to the body via an M25×0.5 thread, allowing users to change focal length as required.

    No. Component Specification
    1 Infrared Lens M25×0.5, multiple focal lengths available
    2 Infrared Camera Module LC221, 384×288 or 640×512
    3 Main Control Board ARM+DSP processor
    4 OLED Display 0.39" 1024×768@50Hz
    5 Housing Aluminium alloy
    6 Battery 1S lithium battery

    7. Ordering Information

    For the T1N series the 640×512 mainstream model is recommended first: it offers superior thermal sensitivity (NETD≤35mK) and longer recognition range, suiting long-range observation and fine temperature analysis. The 384×288 standard economy version suits entry-level scenarios with tighter budgets. A 1280×1024 high-definition model is planned as a future upgrade.

    Model Resolution Lens Notes
    T1N-640 640×512 M25×0.5 standard lens Mainstream recommendation
    T1N-384 384×288 M25×0.5 standard lens Standard economy version

    8. References

    1. LC221 infrared camera module datasheet: /uploads/soft/20241011/1-24101109552L38.pdf

    2. Operating principles of uncooled vanadium oxide microbolometers: Rogalski A., "Infrared Detectors", 2nd Edition, CRC Press, 2011.

    3. Johnson criteria (evaluation of detection / recognition / identification range): Johnson J., "Analysis of Image Forming Systems", Proceedings of the Image Intensifier Symposium, 1958.

    4. LWIR atmospheric window transmittance data: MODTRAN atmospheric radiative transfer model, average transmittance >80% in the 8-14μm band (standard atmosphere, 1km horizontal path).

    【Back】

Need selection advice or a custom solution?

Link-Card provides thermal module selection, secondary development and full-system solution support.

Our sales team will reply to the email or phone number you leave. You can also email sales@link-card.com directly.