Industrial Infrared Thermal Imager: HDMI/AHD/TVI/SDI Multiple Output Formats
Industrial Infrared Thermal Imager: HDMI/AHD/TVI/SDI Multiple Output Formats

1. Overview
The A1T series industrial infrared thermal imagers are built on Link-Card Tech uncooled vanadium oxide infrared detectors, targeting industrial monitoring, equipment inspection and security integration applications. The product family offers four video output formats — HDMI, AHD, SDI and TVI — covering direct-connect displays, coaxial surveillance systems, broadcast-grade transmission and industrial HMI panels. All models additionally support driver-free USB UVC output (in YUV, MJPG or RAW14bits format), allowing professional PC software to capture raw infrared data directly.
The 640×512 resolution is the mainstream recommended configuration for the A1T module, with 1.5W power consumption; 384×288 is available as a standard economy option at 1.2W; and a 1280×1024 high-definition configuration is offered as an upgrade, providing four times the pixel coverage of 640×512 for large-area precision temperature measurement. The module (excluding lens) measures only 32×32×43.70mm and weighs 59g, powered from USB Type-C 5V DC. Its M25×0.5 threaded mount accepts germanium glass infrared lenses of various focal lengths, and the module can be embedded into a wide range of industrial equipment housings to deliver customised thermal imaging capability.
2. Technical Specifications
The table below lists the complete technical specifications for both A1T resolution configurations, with 640×512 as the mainstream recommendation and the 1280×1024 high-definition configuration available on request. On NETD, the 640×512 configuration achieves ≤35mK and the 384×288 configuration ≤40mK, giving the 640×512 version a clear advantage in thermal sensitivity.
| Parameter | 384×288 Configuration | 640×512 Configuration |
|---|---|---|
| Detector Type | Uncooled vanadium oxide infrared detector | Same as left |
| Resolution | 384×288 | 640×512 |
| Pixel Pitch | 12μm | 12μm |
| Spectral Response | 8-14μm | 8-14μm |
| Frame Rate | 25/30/50Hz | 25/30Hz |
| NETD | ≤40mK@25℃,F#1.0 | ≤35mK@25℃,F#1.0 |
| Processor | ARM+DSP | ARM+DSP |
| Memory | 2Gb DDR | 2Gb DDR |
| Shutter Correction | Automatic / manual | Automatic / manual |
| Digital Zoom | 1.0-4.0× | 1.0-4.0× |
| Electronic Compass | Supported | Supported |
| Motion Sensor | Supported | Supported |
| Reticle | Show / hide / move | Same as left |
| Power Consumption | 1.2W | 1.5W |
| Power Supply | USB Type-C 5V DC | USB Type-C 5V DC |
| Dimensions (excl. module) | 32×32×43.70mm | Same as left |
| Weight (excl. module) | 59g | 59g |
| Lens Mount | M25×0.5 | M25×0.5 |
| Operating Temperature | -20℃~60℃ | -20℃~60℃ |
3. System Architecture
The A1T system consists of the infrared optical assembly, the uncooled vanadium oxide detector, the ARM+DSP signal processing platform and the multi-format video output interfaces.
LWIR imaging physics: every object above absolute zero emits infrared radiation. By the Stefan-Boltzmann law, blackbody radiant power density is proportional to the fourth power of temperature (P = εσT⁴, where ε is emissivity and σ is the Stefan-Boltzmann constant, 5.67×10⁻⁸ W·m⁻²·K⁻⁴). The 8-14μm band lies within the long-wave infrared atmospheric window with atmospheric transmittance >80% (1km horizontal path), making it the band of choice for thermal imaging of ground targets. After a detector pixel absorbs target radiation its temperature rises and the resistance of the vanadium oxide (VOx) film changes accordingly (TCR of approximately -2%~-3%/K); the ROIC readout circuit converts this resistance change into an electrical signal. Detector responsivity depends on pixel thermal conductance, heat capacity and TCR; typical NETD for uncooled detectors is 30-50mK.
Signal processing platform: an ARM+DSP dual-core architecture. The ARM core runs control logic (communication, UI, sensor management) while the DSP core executes the real-time image processing pipeline. 2Gb of DDR memory buffers multiple frames for temporal noise reduction. The video output section integrates a different encoder depending on model: HDMI models contain an HDMI transmitter outputting 1024×768@50Hz digital video; AHD/TVI models use a coaxial encoder outputting 720P/PAL analogue video, compatible with existing coaxial surveillance cabling; SDI models use a serial digital interface encoder for broadcast-grade lossless video. The USB UVC interface outputs YUV (compressed preview), MJPG (motion JPEG) or RAW14bits (raw 14bit data) in parallel.
Image processing algorithms: the A1T embeds a complete infrared image processing pipeline; the function of each algorithm is listed in the table below.
| Algorithm | Function |
|---|---|
| NUC | Non-uniformity correction, eliminating detector pixel response variation |
| AGC | Automatic gain control, dynamic range compression |
| 2D/3D Noise Reduction | Joint spatial-temporal noise reduction |
| Pseudo-Colour Mapping | Multiple palettes (white-hot / black-hot / red-hot / blue-green flame / iron red / spectrum) |
| DDE | Digital detail enhancement |
| Bad Pixel Compensation | Replaces defective pixels to preserve image integrity |
| Shutter Correction | Automatic / manual mechanical shutter reference correction |
4. Interface Definition
The defining feature of the A1T series is the range of video output formats available; users select the model matching their integration scenario. Every model also provides USB UVC output for direct capture by PC software.
| Model | Video Output | Physical Interface | Output Resolution |
|---|---|---|---|
| A1T-HDMI | HDMI + USB(UVC) | Type-C | HDMI: 1024×768@50Hz; USB: 384×288/640×512 |
| A1T-AHD | AHD + USB(UVC) | MCX + Type-C | AHD: 720P/PAL; USB: 384×288/640×512 |
| A1T-SDI | SDI + USB(UVC) | MCX + Type-C | SDI: 720P/PAL; USB: 384×288/640×512 |
| A1T-TV | TVI + USB(UVC) | MCX + Type-C | TVI: 720P/PAL; USB: 384×288/640×512 |
USB UVC output formats: the YUV format outputs an AGC-processed 8bit video stream at the detector frame rate, suited to real-time preview. The MJPG format outputs JPEG-compressed frames with low bandwidth requirements, suited to network transmission and storage. The RAW14bits format outputs unprocessed raw 14bit detector data containing the full radiometric information, from which professional software can perform quantitative temperature analysis and custom image processing. The three formats are selectable through the USB descriptor.
5. Application Scenarios
Mine and tunnel high-temperature risk monitoring: in underground roadways and tunnel construction environments, abnormal surrounding-rock temperature can indicate heat hazard or a latent fire risk. The A1T connects directly to an explosion-proof underground display over HDMI, showing the surrounding-rock temperature distribution in real time. Thermal sensitivity of NETD≤40mK resolves temperature differences of 0.04℃, sufficient to distinguish abnormal thermal gradient regions in the rock. SDI models transmit losslessly over long distances to a surface control centre, reaching over 100m on coaxial cable, or further via fibre conversion.
Electrical equipment condition monitoring: high-voltage switchgear, transformers, busbar joints and similar electrical equipment develop local temperature rise when contacts degrade, loads are exceeded or insulation ages. The A1T thermal imager measures equipment surface temperature fields without contact, allowing faults to be predicted from temperature-rise trend analysis. The 640×512 model provides greater pixel coverage, capturing an entire switchgear panel in a single frame. AHD/TVI models integrate into existing coaxial surveillance systems with no re-cabling required.
Pipeline and storage tank inspection: damaged steam pipeline insulation, heating pipeline leaks and tank level detection can all be identified through infrared thermal imaging. Surface temperature at a break in pipeline insulation is markedly higher than along healthy sections, appearing as a bright region in the thermal image. The liquid level line inside a tank is discernible in thermal imagery because of the heat capacity difference between the liquid and gas phases.
Industrial HMI integration: the A1T-HDMI model connects directly to an industrial touch screen or HMI panel over its Type-C interface, embedding the thermal image into a production line monitoring interface. Digital zoom (1.0-4.0×) lets operators magnify a region of interest without changing lenses, and the reticle function supports precise positioning of measurement points.
6. Mechanical Dimensions
The A1T module measures 32×32×43.70mm (excluding lens) and weighs 59g. The M25×0.5 lens mount accepts the full range of Link-Card Tech infrared lenses (9.1mm/13mm/19mm/25mm/35mm/50mm and other focal lengths). The MCX connector (on AHD/SDI/TVI models) is a miniature coaxial connector with a small footprint. The Type-C interface carries both power and USB data. M2.5 mounting holes are provided at the four corners of the PCB for mechanical fixing.
| Dimension Parameter | Value | Notes |
|---|---|---|
| Dimensions (excl. module) | 32×32×43.70mm | Including lens mount |
| Weight (excl. module) | 59g | Including PCB and connectors |
| Lens Mount | M25×0.5 | Threaded connection |
| Mounting Holes | 4×M2.5 | Four-corner fixing |
| Power Supply | 5V DC / Type-C | USB powered |
The A1T series accepts infrared lenses of various focal lengths, allowing users to select flexibly according to inspection distance and required field of view. The standard lens is 25mm; the 9.1mm short focal length suits close-range wide-angle monitoring and the 50mm telephoto suits long-range precision temperature measurement.
| Lens Focal Length | Field of View (FOV) | Application |
|---|---|---|
| 9.1mm | Wide FOV | Close-range wide-angle monitoring / large-area coverage |
| 25mm | Medium FOV | Standard industrial monitoring (standard fit) |
| 35mm | Medium-narrow FOV | Medium to long range inspection |
| 50mm | Narrow FOV | Long-range precision temperature measurement |
7. Ordering Information
The A1T series is offered as six standard models combining output format and resolution. When selecting, first determine the video connection method required by the integration scenario (direct HDMI / coaxial AHD / SDI), then choose the resolution — the 640×512 mainstream model is recommended first, the 384×288 standard economy version suits budget-constrained scenarios, and the 1280×1024 high-definition model is available on request.
| Model | Output Format | Interface | Application |
|---|---|---|---|
| A1T-HDMI-640 | HDMI+USB | Type-C | Mainstream recommendation: HD industrial inspection |
| A1T-AHD-640 | AHD+USB | MCX+Type-C | Mainstream recommendation: HD surveillance integration |
| A1T-SDI-640 | SDI+USB | MCX+Type-C | Mainstream recommendation: HD long-distance transmission |
| A1T-HDMI-384 | HDMI+USB | Type-C | Standard economy version: direct display / HMI |
| A1T-AHD-384 | AHD+USB | MCX+Type-C | Standard economy version: coaxial surveillance integration |
| A1T-SDI-384 | SDI+USB | MCX+Type-C | Standard economy version: broadcast-grade long distance |
8. References
1. LWIR radiation and the Stefan-Boltzmann law: Incropera F.P. et al., "Fundamentals of Heat and Mass Transfer", 7th Edition, Wiley, 2011.
2. Uncooled vanadium oxide microbolometer principles and NETD derivation: Rogalski A., "Infrared Detectors", 2nd Edition, CRC Press, 2011.
3. SDI/AHD/TVI/HD-CVI coaxial high-definition video transmission standard technical white papers.
4. Infrared inspection and diagnosis standard for electrical equipment: DL/T 664-2016, "Application rules of infrared diagnosis for live electrical equipment".
5. USB Video Class (UVC) specification: USB-IF, "USB Device Class Definition for Video Devices", Revision 1.5.